- Centrifuge Tubes[1]
- Laboratory Centrifuge[10]
- Laboratory Heating Equipments[6]
- Laboratory Thermostatic Devices[1]
- Other Lab Supplies[10]
- Petri Dish[1]
- Test Tube[1]
- Other Electrical Equipment[2]
- Water Treatment[2]
- Hospital Cabinets[7]
- Laboratory Furniture[8]
- Healthcare Supplies[2]
- Clinical Analytical Instruments[4]
- Dental Equipments[5]
- Emergency & Clinics Apparatus[1]
- Medical Consumables[5]
- Sterilization Equipments[8]
- Ultrasonic Cleaners[6]
- Drying Equipment[5]
- Mixing Equipment[10]
- Other Chemical Equipment[6]
- Other Pharmaceutical Machinery[1]
- Other Analysis Instruments[10]
- PH Meters[9]
- Instrument Parts & Accessories[9]
- Other Optics Instruments[7]
- Refractometers[1]
- Spectrometers[10]
- Other Physical Measuring Instruments[2]
- Speed Measuring Instruments[2]
- Temperature Instruments[10]
- Testing Equipment[10]
- Weighing Scales[7]
VIS Spectrophotometer VIS-723G
Single beam wavelength scanning in whole wavelength range of 320-1100nm.
1 Single beam wavelength scanning in whole wavelength range of 320-1100nm.
2 Three options for spectral bandwidth selection:5nm, 2nm and 1nm, made according to customer's need and satisfy the requirements of pharmacopoeia.
3 Standard manual 4-cell holder accommadates cells from 5-50mm and changeable to long path length cells up to 100nm.
4 Optimized optics and electronics design, light source and detectors from the world famous manufacturer ensure high performance and reliability.
5 Rich measurement methods: wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, double-wavelength method and triple-wavelength method etc., meet different measurement requirement.
6 Data output can be obtained via a printer port.
7 Parameters and data can be saved for user's convenience.
8 PC controlled measurement can be achieved via a RS-232 interface( USB port)for more accurate and flexible requirement.
Wavelength Range | 320-1100nm |
Spectral Bandwidth | 2nm(5nm, 1nmoptional) |
Wavelength Accuracy | ±0.5nm |
Wavelength Reproducibility | 0.2nm |
Monochromatic | Single beam, plane grating of 1200L/mm |
Photometric Accuracy | ±0.5%T (0-100%T), ±0.002A (0-0.5A), ±0.004A (0.5A-1A) |
Photometric Reproducibility | 0.2%T |
Photometric Range | -0.3-3A |
Working Mode | T,A,C,E |
Stray Light | ≤0.1%T(NaNO2,360nm) |
Baseline Flatness | ±0.002A |
Stability | ≤0.001A/h (at 500nm, after warming up) |
Light Source | Tungsten halogen lamp |
Detector | Silicon photodiode |
Display | 6 inches high light blue LCD |
Power | AC:220V/50Hz, 110V/60Hz,140W |
Dimensions | 530×410×210mm |
Weight | 18kg |